Differences
This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
| techtalk:ih:engctl02 [2020/02/06 17:59] – [Solenoids] hippysmack | techtalk:ih:engctl02 [2023/12/31 18:18] (current) – hippysmack | ||
|---|---|---|---|
| Line 41: | Line 41: | ||
| Reference these threads:\\ | Reference these threads:\\ | ||
| - | http:// | + | https://www.xlforum.net/ |
| - | http:// | + | https://www.xlforum.net/ |
| - | http:// | + | https://www.xlforum.net/ |
| \\ | \\ | ||
| + | |||
| + | |||
| The 1981-later starters are the same Nippon Denso version as used on the Evolution model engines. | The 1981-later starters are the same Nippon Denso version as used on the Evolution model engines. | ||
| Line 52: | Line 54: | ||
| For additonal information, | For additonal information, | ||
| - | | Prestolite Starter. ((photos by sifty of the XLFORUM | + | | Prestolite Starter. ((photos by sifty of the XLFORUM |
| |{{: | |{{: | ||
| + | |||
| + | | 74-E76 Hitachi starter. ((photo by needspeed of the XLFORUM)) | ||
| + | |{{: | ||
| \\ | \\ | ||
| Line 60: | Line 65: | ||
| ====== Solenoid ====== | ====== Solenoid ====== | ||
| - | A typical well-made solenoid as two windings connected to the small terminal. ((Oldwrench of the XLFORUM | + | {{ : |
| - | One coil goes to solenoid case ground and the other goes to the big starter lead. \\ | + | A typical well-made solenoid as two windings connected to the small terminal. ((Oldwrench of the XLFORUM |
| - | When you hit the starter button, battery voltage goes into the solenoid, | + | One coil (HOLD-IN) |
| - | When the plunger pulls in, it brings the contact disc in contact with the big battery and starter terminals. \\ | + | When you hit the starter button, battery voltage goes thru the starter relay into the solenoid |
| - | When that disc connects with the starter terminal, it shorts out the PULL IN windings | + | ·· then goes thru the 'PULL-IN' windings |
| - | If the battery cable is connected to the starter terminal of the solenoid, then the hold in windings will be conducting current. \\ | + | ·· the ' |
| - | That current isn't strong enough to allow the HOLD IN windings to pull in the plunger but the current flow is enough to make the solenoid get really hot. \\ | + | **When these coils are activated together, they pull the plunger |
| - | And if not disconnected, | + | |
| + | When the plunger pulls in, it brings the large contact disc in contact with the big battery and starter terminals. \\ | ||
| + | When that disc connects with the starter terminal, it bypasses | ||
| + | ·· continues supplying power to the HOLD IN windings. \\ | ||
| + | |||
| + | **Make sure that your connections are to the proper large terminals!** | ||
| + | |||
| + | **IT IS IMPORTANT** that you use the __**Large Long** Terminal to connect to the Battery__ and the __**Large Short** Terminal to connect to the Starter Motor__. | ||
| + | |||
| + | If the large terminal connections are swapped, with the battery cable connected to the output | ||
| + | That current isn't strong enough to actually | ||
| + | If left this way, and not disconnected, | ||
| So you don't want to hook up the battery to the terminal used for the starter. \\ | So you don't want to hook up the battery to the terminal used for the starter. \\ | ||
| - | The solenoid will still work at first, but left connected it will burn out either or both of the windings because the HOLD IN windings are constantly conducting. \\ | + | The solenoid will still work at first, but left connected it will burn out either or both of the windings because the windings are constantly conducting. \\ |
| Using an ohm meter would give really confusing readings because you'd see continuity to both case ground and the starter terminal from the solenoid windings connection. | Using an ohm meter would give really confusing readings because you'd see continuity to both case ground and the starter terminal from the solenoid windings connection. | ||
| - | 67 and Up XLH Starter solenoid (71469-65) \\ | + | \\ |
| - | Below, the 1/4" solenoid mounting threads were stripped (nut on the top bolt) so they were tapped out for 8mm cap screws. ((photo by sifty of the XLFORUM | + | |
| + | **67 and Up XLH Starter solenoid (71469-65)**\\ | ||
| + | Below, the 1/4" solenoid mounting threads were stripped (nut on the top bolt) so they were tapped out for 8mm cap screws. ((photo by sifty of the XLFORUM | ||
| 8mm x 1.25 threads have almost exactly the same thread pitch as the original 1/4" thread. \\ | 8mm x 1.25 threads have almost exactly the same thread pitch as the original 1/4" thread. \\ | ||
| - | Then the mounting bracket and and spacer were drilled 8mm and the solenoid was installed using allen head cap screws and spring washers. | + | Then the mounting bracket and and spacer were drilled 8mm and the solenoid was installed using allen head cap screws and spring washers. |
| - | | Starter solenoid (71469-65) ((photo by sifty of the XLFORUM | + | | Starter solenoid (71469-65) ((photo by sifty of the XLFORUM |
| |{{: | |{{: | ||
| \\ | \\ | ||
| - | |||
| - | |||
| ===== Check Solenoid Cover for Conductivity ===== | ===== Check Solenoid Cover for Conductivity ===== | ||