| ====== IH: Electrical System - Sub-02A ====== | ====== IH: Electrical System - Sub-02A ====== | ||
| ====== Bench Testing a Generator ====== | ====== Bench Testing a Generator ====== | ||
| - | Article by sifty of the XLFORUM ((http:// | + | Article by sifty of the XLFORUM ((https://www.xlforum.net/ |
| Some simple diagnostic tests can be done with a multimeter. \\ | Some simple diagnostic tests can be done with a multimeter. \\ | ||
| Line 13: | Line 13: | ||
| {{ : | {{ : | ||
| - | * Generators are fairly simple, they consist of; ((photo by sifty of the XLFORUM ((http:// | + | * Generators are fairly simple, they consist of; ((photo by sifty of the XLFORUM ((https://www.xlforum.net/ |
| * Field windings are designated " | * Field windings are designated " | ||
| * Armature windings are designated as " | * Armature windings are designated as " | ||
| Line 25: | Line 25: | ||
| \\ | \\ | ||
| \\ | \\ | ||
| - | |||
| ====== Brush assembly ====== | ====== Brush assembly ====== | ||
| {{ : | {{ : | ||
| - | The brush plate is easily removable, and inspection/ cleanup should be straight forward. ((photo by sifty of the XLFORUM | + | The brush plate is easily removable, and inspection/ cleanup should be straight forward. ((photo by sifty of the XLFORUM |
| Care must be taken when installing the brush plate. \\ | Care must be taken when installing the brush plate. \\ | ||
| Make sure that the brush- armature connecting wire is not pinched (can short circuit to the frame). \\ | Make sure that the brush- armature connecting wire is not pinched (can short circuit to the frame). \\ | ||
| Line 37: | Line 36: | ||
| Ensure the connecting wires are tightened in a position to allow full movement. \\ | Ensure the connecting wires are tightened in a position to allow full movement. \\ | ||
| And make sure the bare end of the armature brush wire does not contact the case or end cap on assembly. | And make sure the bare end of the armature brush wire does not contact the case or end cap on assembly. | ||
| + | |||
| ====== Terminal insulation ====== | ====== Terminal insulation ====== | ||
| - | |||
| The terminals must be insulated between where they go through the case and connect to the windings. \\ | The terminals must be insulated between where they go through the case and connect to the windings. \\ | ||
| There will be some sort of fiber or plastic bushing around them at this point. \\ | There will be some sort of fiber or plastic bushing around them at this point. \\ | ||
| Line 47: | Line 46: | ||
| ====== Armature ====== | ====== Armature ====== | ||
| - | |||
| Testing on the Ohms scale between each commutator segment and the exposed iron core will indicate any short circuits to ground. \\ | Testing on the Ohms scale between each commutator segment and the exposed iron core will indicate any short circuits to ground. \\ | ||
| Each segment should show very high resistance to ground (ideally in the Mega-ohms range). \\ | Each segment should show very high resistance to ground (ideally in the Mega-ohms range). \\ | ||
| Line 58: | Line 56: | ||
| With the generator cleaned, assembled and on the bench, some simple test with the multimeter in the Ohms scale can tell you a lot about its electrical health. \\ | With the generator cleaned, assembled and on the bench, some simple test with the multimeter in the Ohms scale can tell you a lot about its electrical health. \\ | ||
| The figures noted here were the results from 2 generators (different models). \\ | The figures noted here were the results from 2 generators (different models). \\ | ||
| - | They should be reasonably typical the standard 12V Harley generator. ((photo by sifty of the XLFORUM | + | They should be reasonably typical the standard 12V Harley generator. ((photo by sifty of the XLFORUM |
| \\ | \\ | ||
| {{ : | {{ : | ||
| - | Field winding resistance: \\ | + | **Field winding resistance**: \\ |
| Placing the leads across the A and F terminals will give you the effective resistance of the field windings (2 windings in series). \\ | Placing the leads across the A and F terminals will give you the effective resistance of the field windings (2 windings in series). \\ | ||
| The armature circuit is not included as in a healthy generator there is no return path via ground to the meter. \\ | The armature circuit is not included as in a healthy generator there is no return path via ground to the meter. \\ | ||
| This should be around the 5.8 ohm mark, a higher figure indicates a possible open circuit, and a lower figure may mean a winding is shorting out somewhere. | This should be around the 5.8 ohm mark, a higher figure indicates a possible open circuit, and a lower figure may mean a winding is shorting out somewhere. | ||
| - | Armature resistance: \\ | + | **Armature resistance**: \\ |
| Placing one lead on a good, clean ground point on the case (shiny metal) and the other on the A terminal, will follow the path through the armature to ground. \\ | Placing one lead on a good, clean ground point on the case (shiny metal) and the other on the A terminal, will follow the path through the armature to ground. \\ | ||
| This should be very low, typically less than 0.6 ohms but can vary as it depends on the brush/ | This should be very low, typically less than 0.6 ohms but can vary as it depends on the brush/ | ||
| - | Total resistance: \\ | + | **Total resistance**: \\ |
| Placing the leads on a good ground point and the F terminal effectively measures the field plus armature circuits in series (from the F terminal, through the field windings, then through the armature to ground). \\ | Placing the leads on a good ground point and the F terminal effectively measures the field plus armature circuits in series (from the F terminal, through the field windings, then through the armature to ground). \\ | ||
| As a quick check, this result should be very close to the values of the previous tests added together. | As a quick check, this result should be very close to the values of the previous tests added together. | ||
| Line 78: | Line 76: | ||
| {{ : | {{ : | ||
| - | With the brushes out there are a couple of further tests available: ((photo by sifty of the XLFORUM | + | With the brushes out there are a couple of further tests available: ((photo by sifty of the XLFORUM |
| - | Winding insulation: \\ | + | **Winding insulation**: \\ |
| Placing one lead on a clean ground point of the casing, and the other on either terminal (do both) should give a very high reading (ideally in the Mega-ohms range). \\ | Placing one lead on a clean ground point of the casing, and the other on either terminal (do both) should give a very high reading (ideally in the Mega-ohms range). \\ | ||
| This indicates the windings are not shorting to ground anywhere. | This indicates the windings are not shorting to ground anywhere. | ||
| - | Winding current: \\ | + | **Winding current**: \\ |
| Connecting the battery through the multimeter in the Amps scale should result in a DC current of around 2 amps. \\ | Connecting the battery through the multimeter in the Amps scale should result in a DC current of around 2 amps. \\ | ||
| Ohms law states V = IR, so with 12V and a resistance of around 6 ohms I = V/R which gives the 2 amps (will vary in practice as your winding resistance and battery voltage will differ). \\ | Ohms law states V = IR, so with 12V and a resistance of around 6 ohms I = V/R which gives the 2 amps (will vary in practice as your winding resistance and battery voltage will differ). \\ | ||
| - | Motor test: \\ | + | **Motor test**: \\ |
| This is probably the best indication, as a generator that will motor with voltage applied indicates all is well with the commutator / brush assembly. \\ | This is probably the best indication, as a generator that will motor with voltage applied indicates all is well with the commutator / brush assembly. \\ | ||
| Jumper leads from a good battery were used and a short piece of wire (applied +12V to the A terminal, and -12V to the case and F terminal simultaneously). \\ | Jumper leads from a good battery were used and a short piece of wire (applied +12V to the A terminal, and -12V to the case and F terminal simultaneously). \\ | ||